KB² Fiber-Optic Sheet Break Detector
Non-contact optical measurement
The KB2 fiber optic sheet break detection system is designed to monitor sheet breaks in harsh environments, it is proven with hundreds of installations around the world. The non-contact sensor is placed above or under the web to be monitored.
KB2 is suitable for dirt, steam and high temperature installations or where space is limited. The air-purged sensor head stays clean and is not affected by dirt, steam or high temperatures.
RGB Color and IR measurement
The KB2 has both, RGB or Infrared light sources to perform superiorly with all paper and board grades and applications regardless of colors. The RGB color measurement can handle all sheet, wire and felt colors providing reliable break detection. In addition to open-draw applications the breaks can be detected against felt, wire, or even against a cylinder.
Fast break detection
The KB2’s digital signal processing technology measures all signals at a thousand times per second. KB2 is immune to ambient light changes by measuring the backlight intensity. The break detection delay is a minimum of 15ms - with digital filtration user can select how many
measurement cycles are used for break alarm.
Easy to set up
The KB2 Display Unit’s large display and logical user interface allows easy setup of the break detection by selecting the measurements which give the highest signal difference. Break and maintenance alarms are wired to the PLC or DCS.
KB2 has optional color measurement PC software for monitoring and includes data collection feature. 4-20 mA current outputs for the signal levels are available as an option.
Electronics located outside harsh environment
KB2 is very reliable even in a 100% humidity environment. While the sensor head is exposed to high temperatures, the electronics unit is mounted outside the machine hood to convenient location using fiber optic cable. Fiber optics is available in lengths of 6, 9 and 12 meters.
SPECIFICATIONS |
|
AMBIENT TEMPERATURE |
Sensor head and fiber optic cable: -10 to 180 ºC (15 ºF to 356 ºF)
Electronics unit: -10 to 60 ºC (15 ºF to 140 ºF) |
FIBER OPTIC CABLE |
KB2/6: 6 m (20’), KB2/9: 9 m (30’) or KB2/12: 12m (40’) |
FIBER OPTIC CABLE
CONDUIT |
Requires flexible airtight conduit 19 mm (3/4”) ID min, available as an
option. |
CONDUIT CONNECTION |
19 mm (3/4 ”) BSP |
INSTALLATION |
Sensor distance from the web 5...30 cm (2...12”). |
LED PULSE FREQUENCY |
1 kHz |
POWER SUPPLY |
90 - 264 VAC, 50/60 Hz |
POWER CONSUMPTION |
15 W |
ENCLOSURE CLASS |
IP 66 (Nema 4X) |
PURGE AIR CONNECTION |
Dry instrument air, 6/4 mm (1/4”) connector, normal consumption
80l/min |
DIGITAL OUTPUTS |
2 x Closing or opening contact max. 250 VAC, 2A; 220VDC, 2 A for
Break signal and Maintenance alarm |
ALARM OUTPUT DELAY |
Min. 15 ms from the actual break |
ANALOG OUTPUTS |
Optional 3 pcs 4 - 20 mA max 600 ohm |
PC CONNECTION |
Optional KB2-PC terminal program for set up and monitoring
available. RS 485 connection to PC. Optional RS 485 / USBconverter
available for PC |
DIMENSIONS (L x H x D) AND
WEIGHT |
Electronics Unit 323 x 237 x 70 mm (12,7 x 9,3 x 2,8”), 3 kg (6,6lbs)
Sensor head Ø 33 mm (11/4 ”) SS316, pipe 1500 mm (59”) long, 4 kg
(9lbs) |